All Relations between Epilepsy and mr

Publication Sentence Publish Date Extraction Date Species
P Boon, L Calliauw, J De Reuck, I Hoksbergen, E Achten, E Thiery, J Caemaert, A De Somer, D Deco. Clinical and neurophysiological correlations in patients with refractory partial epilepsy and intracranial structural lesions. Acta neurochirurgica. vol 128. issue 1-4. 1995-03-09. PMID:7847146. twenty patients (13 males, 7 females), who presented with refractory partial epilepsy and a ct and/or mr detected intracranial intra-axial structural lesion were admitted to the university of gent epilepsy monitoring unit. 1995-03-09 2023-08-12 Not clear
A Imamura, K Sugai, S Watanabe, F Hamada, T Kurashige, S Takashim. High intensity in the globus pallidus on proton and T2-weighted MRI in a case of dentato-ruburo-pallido-luysian atrophy of myoclonus epilepsy type. Acta paediatrica Japonica : Overseas edition. vol 36. issue 5. 1995-02-14. PMID:7825457. although marked atrophy of the tegmentum of the mid-brain is a known computed tomography (ct) and magnetic resonance imaging (mri) feature in patients with dentato-ruburo-pallido-luysian atrophy (drpla), this is the first report of marked high signal intensity of the globus pallidus on proton and t2-weighted mr images in a patient in the early stage of drpla of the myoclonus epilepsy type. 1995-02-14 2023-08-12 Not clear
G D Jackson, R A Grünewald, A Connelly, J S Dunca. Quantitative MR relaxometry study of effects of vigabatrin on the brains of patients with epilepsy. Epilepsy research. vol 18. issue 2. 1994-12-07. PMID:7957035. quantitative mr relaxometry study of effects of vigabatrin on the brains of patients with epilepsy. 1994-12-07 2023-08-12 rat
R A Grünewald, G D Jackson, A Connelly, J S Dunca. MR detection of hippocampal disease in epilepsy: factors influencing T2 relaxation time. AJNR. American journal of neuroradiology. vol 15. issue 6. 1994-09-23. PMID:8073986. mr detection of hippocampal disease in epilepsy: factors influencing t2 relaxation time. 1994-09-23 2023-08-12 Not clear
R A Bronen, A W Anderson, D D Spence. Quantitative MR for epilepsy: a clinical and research tool? AJNR. American journal of neuroradiology. vol 15. issue 6. 1994-09-23. PMID:8073987. quantitative mr for epilepsy: a clinical and research tool? 1994-09-23 2023-08-12 Not clear
S N Breiter, S Arroyo, V P Mathews, R P Lesser, R N Bryan, P B Barke. Proton MR spectroscopy in patients with seizure disorders. AJNR. American journal of neuroradiology. vol 15. issue 2. 1994-06-17. PMID:8192088. to evaluate the ability of proton mr spectroscopy to detect metabolic abnormalities in the seizure focus of humans with epilepsy. 1994-06-17 2023-08-12 Not clear
G Honghan, K Hiraishi, T Matsuoka, Y Tanaka, Y Hisada, A Sagami, K Ashina, Y Uesugi, I Adachi, T Shimiz. [MR imaging findings in patients with epilepsy]. Nihon Igaku Hoshasen Gakkai zasshi. Nippon acta radiologica. vol 54. issue 2. 1994-04-06. PMID:8121777. [mr imaging findings in patients with epilepsy]. 1994-04-06 2023-08-12 Not clear
G Honghan, K Hiraishi, T Matsuoka, Y Tanaka, Y Hisada, A Sagami, K Ashina, Y Uesugi, I Adachi, T Shimiz. [MR imaging findings in patients with epilepsy]. Nihon Igaku Hoshasen Gakkai zasshi. Nippon acta radiologica. vol 54. issue 2. 1994-04-06. PMID:8121777. we retrospectively examined the mr imaging (mri) findings in 144 patients with epilepsy (31 with temporal lobe epilepsy and 113 with other epilepsies). 1994-04-06 2023-08-12 Not clear
G Honghan, K Hiraishi, T Matsuoka, Y Tanaka, Y Hisada, A Sagami, K Ashina, Y Uesugi, I Adachi, T Shimiz. [MR imaging findings in patients with epilepsy]. Nihon Igaku Hoshasen Gakkai zasshi. Nippon acta radiologica. vol 54. issue 2. 1994-04-06. PMID:8121777. therefore we recommend horizontal and/or vertical sections of hippocampus in mr imaging of all patients with epilepsy. 1994-04-06 2023-08-12 Not clear
G Honghan, K Hiraishi, T Matsuoka, Y Tanaka, Y Hisada, A Sagami, K Ashina, Y Uesugi, I Adachi, T Shimiz. [MR imaging findings in patients with epilepsy]. Nihon Igaku Hoshasen Gakkai zasshi. Nippon acta radiologica. vol 54. issue 2. 1994-04-06. PMID:8121777. even though mr findings may reflect some secondary lesions, mri will shed some light on the proper understanding of epilepsy. 1994-04-06 2023-08-12 Not clear
M A Merriam, R A Bronen, D D Spencer, G McCarth. MR findings after depth electrode implantation for medically refractory epilepsy. AJNR. American journal of neuroradiology. vol 14. issue 6. 1994-02-10. PMID:8279329. mr findings after depth electrode implantation for medically refractory epilepsy. 1994-02-10 2023-08-12 Not clear
M A Merriam, R A Bronen, D D Spencer, G McCarth. MR findings after depth electrode implantation for medically refractory epilepsy. AJNR. American journal of neuroradiology. vol 14. issue 6. 1994-02-10. PMID:8279329. to evaluate using mr imaging chronic changes in the brain parenchyma after electroencephalography depth electrode placement in patients with medically refractory epilepsy. 1994-02-10 2023-08-12 Not clear
M R Sperlin. Neuroimaging in epilepsy: recent developments in MR imaging, positron-emission tomography, and single-photon emission tomography. Neurologic clinics. vol 11. issue 4. 1994-02-03. PMID:8272037. neuroimaging in epilepsy: recent developments in mr imaging, positron-emission tomography, and single-photon emission tomography. 1994-02-03 2023-08-12 Not clear
M R Sperlin. Neuroimaging in epilepsy: recent developments in MR imaging, positron-emission tomography, and single-photon emission tomography. Neurologic clinics. vol 11. issue 4. 1994-02-03. PMID:8272037. pet, spect, and mr imaging are valuable techniques in the diagnosis and treatment of the epilepsies. 1994-02-03 2023-08-12 Not clear
M R Sperlin. Neuroimaging in epilepsy: recent developments in MR imaging, positron-emission tomography, and single-photon emission tomography. Neurologic clinics. vol 11. issue 4. 1994-02-03. PMID:8272037. mr imaging is also a valuable diagnostic tool in the routine care of epilepsy patients. 1994-02-03 2023-08-12 Not clear
P M Mathews, F Andermann, K Silver, G Karpati, D L Arnol. Proton MR spectroscopic characterization of differences in regional brain metabolic abnormalities in mitochondrial encephalomyopathies. Neurology. vol 43. issue 12. 1994-01-13. PMID:8255444. localized brain proton mr spectra were acquired from patients with different mitochondrial encephalomyopathies (myoclonus epilepsy with ragged-red fibers [merrf], kearns-sayre syndrome [kss], and mitochondrial encephalomyopathy, lactic acidosis, and stroke-like episodes [melas]). 1994-01-13 2023-08-12 Not clear
G D Jackson, A Connelly, J S Duncan, R A Grünewald, D G Gadia. Detection of hippocampal pathology in intractable partial epilepsy: increased sensitivity with quantitative magnetic resonance T2 relaxometry. Neurology. vol 43. issue 9. 1993-10-25. PMID:8414034. we investigated 50 adult outpatients suffering from intractable partial epilepsy with mri optimized to detect hippocampal and cortical gray matter abnormalities, and with mr t2 relaxation mapping. 1993-10-25 2023-08-12 Not clear
G Layer, F Träber, U Müller-Lisse, J Bunke, C E Elger, M Reise. ["Spectroscopic imaging." A new MR technique in the diagnosis of epilepsy?]. Der Radiologe. vol 33. issue 4. 1993-07-08. PMID:8506405. a new mr technique in the diagnosis of epilepsy?]. 1993-07-08 2023-08-12 Not clear
K Bootsveld, F Träber, W A Kaiser, G Layer, C E Elger, A Hufnagel, J Gieseke, M Reise. [Intracranial ECoG electrodes. Location determination using three-dimensional reconstruction of MR data of the brain as a component of the presurgical diagnosis of epilepsy]. Der Radiologe. vol 33. issue 4. 1993-07-08. PMID:8506406. location determination using three-dimensional reconstruction of mr data of the brain as a component of the presurgical diagnosis of epilepsy]. 1993-07-08 2023-08-12 Not clear
J Zhang, C L Wilson, M F Levesque, E J Behnke, R B Lufki. Temperature changes in nickel-chromium intracranial depth electrodes during MR scanning. AJNR. American journal of neuroradiology. vol 14. issue 2. 1993-04-19. PMID:8456738. the authors sought to determine whether there are any heating effects of 1.5-t mr scanning upon nickel-chromium electrodes and to confirm the safety of scanning these electrodes after intracranial surgical implantation in epilepsy patients. 1993-04-19 2023-08-12 Not clear